Sorbents:
+7 (343) 371 25-30 sorb@bk.ru
Chemical Analysis:
+7 (343) 371 31-12 sorb@bk.ru
ENG

Products

Sorbent NIKET on the basis of Nickel Ferrocyanide selectively removes  from aqueous solutions of cesium ions, and thallium, to a lesser extentions of transition and other metals. The presence in the solution of sodium and potassium ions does not reduce the capacity of the sorbent for cesium.

ABOUT PRODUCT
HOW TO USE

Sorbent NIKET is an inorganic sorbent based on nickel ferrocyanide. Available in two versions: NIKET and NIKET-K (composite).

NIKET-K is a microparticle nickel ferrocyanide, chemically fixed on the granules of natural aluminosilicate (opal).

Nickel ferrocyanide selectively removes  ions of cesium and thallium from aqueous solutions, and also ions of transition and other metals. The presence in the solution of sodium and potassium ions does not reduce the capacity of the sorbent for cesium.

STANDART CHARACTERISTICS

 

Modification of sorbent

NIKET

NIKET-K

Extracts

Cs

Cs

Salt concentrations

Up to 500 g/dm3

Up to 500 g/dm3

​Based on

​Nickel Ferrocyanide

​Nickel Ferrocyanide

​Inorganic

​Yes

​Yes

​Stable

​Yes

​Yes

Carrier

None

Aluminosilicate

Form

Powder

​Solid granules

​Bulk density, kg/l

0.9

0.6

​Size of 10%
grains, mm

less 0.3

0.3-1.7

Decontamination factor

2000-6000, up to millions

2000-6000, up to millions

​Capacity typically (BV)

-

60 000 - 300 000

​Capacity typically (l/kg)

20 000 - 500 000

120 000 - 500 000

​Operating pH area

2-13

2-13

​Max. operating temperature (°C)

100

80

Service flow rate typically (BV/h)​

​-

​10-20

Removal of cesium radionuclides under static conditions (an addition of sorbent into the solution, followed by stirring and separation) NIKET is recommended in an amount of 0.5 - 1% of volume of the cleaning solution. If contact time is not less than 2 hours, the recovery rate of ions is not less than 99%.

In a dynamic mode, it is recommended to use NIKET-filtering solution with the speed of 10 column volumes per hour at an height of sorbent layer at least 30 cm. The optimum ratio of height to diameter of the sorbent column is 2.5 – 3.5.